I. outside air, J. fan kit, H. glass doors – Heatiator Heatilator Wood Burning Fireplace SC60 User Manual

Page 9: K. vented gas log sets & gas log lighters, L. optional components, M. clear space

Advertising
background image

9

FULLY OPEN

CORRECT

PARTLY CLOSED

INCORRECT

PARTLY OPEN

INCORRECT

FULLY CLOSED

CORRECT

Figure 2.2 Operating Positions of Bi-fold Doors

WARNING! Risk of Fire and Smoke! Fireplaces

equipped with doors should be operated only with

doors fully open or doors fully closed. If doors are left

partly open, gas and fl ame may be drawn out of the

fi replace opening.

I. Outside Air

The outside air kit supplies some fresh combustion air for

your fi replace. It may help reduce the effects of negative

air pressure. (See Section 5.D.)
• Refer to Figure 2.1 for location of control

• Close the inlet to prevent cold drafts when the fi replace

is not being used.

CAUTION! Risk of Burns! The outside air control

handle is HOT when fi replace is in operation. Adjust

BEFORE lighting fi re.

J. Fan Kit

• Activate wall switch. See also: Section 7.F.

WARNING! Risk of Fire! Install ONLY doors ap-

proved by Hearth & Home Technologies, Inc.

• Glass doors are optional.

• Refer to Figure 2.2 for how to properly use them.

H. Glass Doors

48 in. (1219 mm)

Clear Space

Front of Fireplace

12 in. (305 mm)

Clear Space

Sides of Fireplace

(from the FP

opening)

Figure 2.3 Clear Space

K. Vented Gas Log Sets & Gas Log Lighters

• Optional

• Vented gas logs or gas log lighters can be installed in

this fi replace. Follow the instructions provided with the

accessory for operation.

L. Optional Components

• Other options may be available

• Consult your dealer/distributor

M. Clear Space

• Do not place combustible objects within areas indicated

in Figure 2.3.

WARNING! DO NOT place combustible objects in front

of the fi replace. High temperatures may ignite clothing,

furniture or draperies.

• Mantel - avoid placing candles and other heat-sensitive

objects on mantel or hearth. Heat may damage these

objects.

WARNING! Risk of Fire or Asphyxiation!

DO NOT install unvented gas logs.

• Damper must be locked open.

• Gas fl ame may generate fumes.

WARNING! Risk of Fire! DO NOT install and or use

any component not approved by Hearth & Home Tech-

nologies Inc.

Heatilator • SC60 • 32838 • Rev AG • 7/12

Advertising