3 panel mounting the video recorder, Caution, 1 recommendations – Honeywell VRX180 User Manual

Page 29: 2 external dimensions and cut-out, Installation video recorder - user manual 15, Prepare panel cut-out as detailed below

Advertising
background image

Installation

Video Recorder - User Manual

15

2.3 Panel mounting the video recorder

2.3.1 Recommendations

This video recorder is designed to operate under specific conditions. If you need more information, refer to the
product specification sheet.

2.3.2 External dimensions and cut-out

Prepare panel cut-out as detailed below:

0

0

0

317

12.48

320

12.60

310

12.21

45

1.77

40 max.

1.55

10.83

275

10.95

+0.06

10.95

+0.06

> 75

> 3

> 7

5

> 3

0

278

+1.5

0

millimeters

inches

278

+1.5

NOTE: Maximum panel thickness 40 mm (1.55")

CAUTION

The maximum temperature inside the cabinet should not exceed the ambient conditions specific for the
video recorders.
The video recorder must be mounted into a panel to limit operator access to the rear terminals.
Failure to comply with these instructions may result in product damage.