Section ii - installation, Scope, Certification requirements – Honeywell KMA28 User Manual

Page 9: Cooling requirements, Mounting requirements, 2 section ii - installation -1, General information -1, Scope -1, Ertification, Equirements

Advertising
background image

Bendix/King

KMA28

Audio Amplifier/Intercom/Marker Beacon Receiver

006-10565-0000

Page 2-1

Rev. 0, Sept. 2000

Section II - Installation

2.1 GENERAL

INFORMATION

2.1.1 SCOPE

This section provides detailed installation and interconnect instructions for the Honey-
well, Inc. KMA28 Audio Selector Panel/Intercom System with internal Marker Beacon.
Please read this manual carefully before beginning any installation to prevent damage and
post-installation problems. Installation of this equipment requires special tools and
knowledge.

2.1.2 Certification

Requirements

When the digital audio warning system is installed in a certified aircraft, certification ba-
sis is the installer’s responsibility. Due to the variety and options available for interface,
Honeywell will only provide manufacturers’ data for our equipment interface.

2.2

Unpacking and Preliminary Inspection

Use care when unpacking the equipment. Inspect the units and parts supplied for visible
signs of shipping damage. Examine the unit for loose or broken buttons, bent knobs, etc.
Verify the correct quantity of components supplied with the list in Section 1.6. If any
claim is to be made, save the shipping material and contact the freight carrier. Do NOT
return units damaged in shipping to Honeywell. If the unit or accessories shows any sign
of external shipping damage, contact Honeywell to arrange for a replacement. Under no
circumstances attempt to install a damaged unit in an aircraft. Equipment returned to
Honeywell for any other reason should be shipped in the original packaging, or other UPS
approved packaging.

2.3

Equipment Installation Procedures

2.3.1 Cooling

Requirements

Forced air cooling of the KMA 28 is not required. However the unit should be kept away
from heat producing sources (i.e. defrost or heater ducts, dropping resistors, heat produc-
ing avionics) without adequate cooling air provided.

2.3.2 Mounting

Requirements

The KMA 28 must be rigidly mounted to the instrument panel of the aircraft structure and
within view and reach of the pilot position(s). Installation must comply with FAA Advi-
sory Circular AC 43.13-2A. The unit may be mounted in any area where adequate clear-
ance for the unit and associated wiring bundle exist.

Avoid installing the audio panel close to high current devices or systems with high-
voltage pulse type outputs, such as DME or transponders.