Chapter 3: FR-6804/FR-6804-1 Frames

Overview

12

6800/7000 Series - Frames and Power Supplies Installation and Operation Manual

The GPI is made up of two parts:

A fault sensing circuit within each power supply that monitors the
primary circuit and the two output voltages.

A relay that provides isolation between Leitch equipment and the
GPI output connector at the rear of the frame.

There are three connections provided for GPI reporting:

Normally closed (NC)

Normally open (NO)

Ground

To comply with SMPTE standards, the product uses the NC output and
ground. The relay has two states for GPI reporting:

OPEN:

An open output signifies that the GPI relay is activated and the

power supplies in the frame are present and operating correctly.

CLOSED:

A closed output signifies that the GPI relay has been

de-activated indicating an internal fault in either of the power
supplies or a loss of power to one or both of the supplies.