Installing w8735b module housing onto subbase – Honeywell W8735B User Manual

Page 6

Advertising
background image

TELEPHONE ACCESS MODULE

69-1352

6

Fig. 9. Telephone installation wiring including

monitored security system.

Installing W8735B Module Housing Onto
Subbase

After subbase is mounted and wiring complete, install the
module housing onto the subbase:

1.

Align the subbase and the module housing and
press together; see Fig. 10.

2.

Insert the 2 ¾ in. screws (provided) into the holes.

3.

Tighten screws; be careful not to over tighten.

4.

Connect and insert 9 Vdc alkaline battery.

NOTE:

9 Vdc alkaline battery is optional; however,
when the battery is installed in the W8735B, the
power outage alert option is available.

5.

Replace the cover. See Fig. 11.

6.

Insert the module cover latch pin; see Fig 12.

7.

Apply power to the system.

IMPORTANT

The Telephone Access Module does not answer
within the first 90 seconds after applying power
or anytime power is disconnected.

8.

Do not attempt to dial in to the Telephone Access
Module for the first 90 seconds after applying
power to allow the Telephone Access Module time
to generate its user menu.

Fig. 10. Installing module onto subbase.

M14805

PHONE

OUT

LINE

IN

TO HOUSE
TELEPHONES

USE EITHER RJ11 TELEPHONE CONNECTORS OR OPTIONAL
TELEPHONE CONNECTIONS.

TO TELEPHONE LINE

TO
SECURITY
SYSTEM
TELEPHONE
OUT

Ln 1

Ln 2

Ph 1

Ph 2

SUBBASE

SECURITY SYSTEM
PANEL

MODULE

1

1

1

NOT
USED

M14769

SUBBASE

MODULE

2-3/4 IN. (70)

SCREW (2)

BATTERY

BATTERY

CONNECTOR

Advertising