Wiring, Truedry dh150 – Honeywell TRUEDRY DH150 User Manual

Page 11

Advertising
background image

TrueDRY DH150

9

69-2271EFS—01

Wire the TrueDRY DH150 according to the diagram that applies to your desired operation.

Follow this diagram for ducted operation with an external humidity control.

Wiring

TrueDRY

HVAC

MECHANICAL

DEHUMIDISTAT

THERMOSTAT

G

Y

W

R

Rc

G

Y

W

R

C

M27797

DRY

CONTACTS

+

+

FAN

C

DPDT RELAY,

2.6A

DHUM

R

TrueDRY

HVAC

MECHANICAL

DEHUMIDISTAT

THERMOSTAT

G

Y

W

R Rc

G

Y

W

R

C

M27798

DRY

CONTACTS

DHUM

+

+

R

FAN

C

DPDT

RELAY,

2.6A

EARD-6

AT120

R
C

DAMPER

AUX

REMOTE

W8150A

G

R
C
C

W

G

For ducted operation with external humidity and ventilation control, follow this diagram.