Schematic Diagram

2. Refrigerant Flow Diagram

KFR-33GWE

AC,230V/50Hz

1220W/1260W

3300W/3550W

8m/80

15m

3

450m /h

R22/1.30kg

1. Main specifications of the product

Type

Power source

Power consumption of input

(cooling/heating)

Power (cooling/heating)

Air flow (high)

Refrigeration dose/consumption

Maximum remote control range/

angle range

Maximum length of the connect tube

19

KFR-28GWE

AC,230V/50Hz

1000W/1020W

2800W/3200W

8m/80

15m

3

450m /h

R22/1.27kg

KFR-25GWE

AC,230V/50Hz

950W/950W

2500W/3000W

8m/80

15m

3

450m /h

R22/0.84kg

KFR-2101GWE

AC,230V/50Hz

750W/710W

2100W/2300W

8m/80

15m

3

340m /h

R22/0.70kg

KFR-3201GWE

AC,230V/50Hz

1250W/1400W

3200W/3750W

8m/80

15m

3

420m /h

R22/1.18kg

Indoor unit

H

e

a

t

e

x

c

h

a

n

g

e

r

H

e

a

t

e

x

c

h

a

n

g

e

r

Wide tube

Narrow tube

Outdoor unit

Wide
service
valve

Accumulator

Compressor

4-way valve

Capillary

Narrow
service
tube

Cooling cycle

Heating cycle

Capillary

Check valve

3. Permitted ambient temperature for the air conditioner is following:-7

~+43

(GB/T 7725-1996)