Honeywell Chronotherm IV T8602D User Manual

T8602d chronotherm® iv programmable thermostats, Mercury notice, Application

Advertising
background image

® U.S. Registered Trademark
Copyright © 2003 Honeywell International Inc. •

• All Rights Reserved

INSTALLATION INSTRUCTIONS

69-1510-4

T8602D Chronotherm® IV

Programmable Thermostats

APPLICATION

The T8602 Chronotherm® IV Programmable Thermostat
provides electronic control of 24 Vac single-stage heating
and cooling systems or 750 mV heating and 750 mV

cooling. Refer to Table 1 for a general description of the
thermostat. All T8602 Thermostats are powered by
batteries.

MERCURY NOTICE

If this control is replacing a control that contains
mercury in a sealed tube, do not place your old
control in the trash. Dispose of properly.

Contact your local waste management authority
for instructions regarding recycling and the
proper disposal of the old control.

INSTALLATION

When Installing this Product...

1. Read these instructions carefully. Failure to follow

the instructions can damage the product or cause
a hazardous condition.

2. Check the ratings given in the instructions and on

the product to make sure the product is suitable for
your application.

3. Installer must be a trained, experienced service

technician.

4. After completing installation, use these instructions

to check out the product operation.

Location

Install the thermostat about 1.5m (5 ft) above the floor in
an area with good air circulation at average temperature.
See Fig. 1.

Do not install the thermostat where it can be affected by:
— drafts, or dead spots behind doors and in corners.
— hot or cold air from ducts.
— radiant heat from sun or appliances.
— concealed pipes and chimneys.
— unheated (uncooled) areas such as an outside wall

behind the thermostat.

Wallplate Installation

The thermostat can be mounted horizontally on the wall
or on a 50.8 mm x 101.6 mm (2 in. x 4 in.) wiring box.
Position wallplate horizontally on the wall or on a
50.8 mm x 101.6 mm (2 in. x 4 in.) wiring box.

1. Position and level the wallplate (for appearance

only). The thermostat will function properly even
when not level.

2. Use a pencil to mark the mounting holes. See Fig.

2.

3. Remove the wallplate from the wall and drill two

4.76 mm (3/16 in.) holes in the wall (if drywall) as
marked. For firmer material such as plaster, drill
two 5.56 mm (7/32 in.) holes. Gently tap anchors
(provided) into the drilled holes until flush with the
wall.

4. Position the wallplate over the holes, pulling wires

through the wiring opening.

5. Loosely insert the mounting screws into the holes.
6. Tighten mounting screws.

Table 1. Description of T8602 Thermostats.

T8602

System

Changeover

System

Selection

Fan

Selection

Comments

D

Heat-Cool

Manual or
Automatic

Selectable

Heat-Off-Cool or

Heat-Off-Cool-Auto

On-Auto

System and fan selections are done
by keyboard.

Advertising