Henny Penny HDS-200 User Manual

Henny Penny Refrigerators

Advertising
background image

Model HDS-200/300

4-1. TROUBLESHOOTING GUIDE

Product not

Cold well or hot well not

• Check plugs under table-top

holding

plugged-in

on french fry end of HDS-300

temperature

Product held too long

• Only hold product for

recommended times

Cold well setting turned

• Turn control setting to about 6

Compressor overheated

• Clean condenser coil

Product not a proper

• Be sure product is at proper

temperature when placed

temperature

into unit

Defective fuse for refrigeration

• Replace 15 amp fuse

unit

Refrigeration unit runs

Frost build-up

• Defrost unit

constantly

Condensor coil dirty

• Clean condenser coil

Power switch on but

Open Circuit

• Plug unit in

no power to unit

• Check circuit breaker

• Check 15 amp fuses

• Check cord and plug

for loose connection

Not all lights

Faulty light bulbs

• Replace with new bulb,

on

per Light Bulb Replacement
Section

Lights will

Defective fuse

• Replace 15 amp fuse

not turn on

PROBLEM

CAUSE

CORRECTION

SECTION 4. TROUBLESHOOTING

4-1

605

Advertising