J. control module operation – Heat & Glo Fireplace Heat & Glo 350TRSILP-AUF User Manual

Page 14

Advertising
background image

Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. R • 2/13

14

Note: If the module is in LOCK-OUT mode, resetting the

circuit breaker to the appliance will also reset the module.

Note: For units installed in Australia, the residence’s 220/240

wall outlet to which this appliance’s power cord is connected,

must be wired to an in-line on/off switch. This is required for

servicing and/or resetting the control module in the event of

a control module LOCK-OUT.

Figure 2.3 Control Module

J. Control Module Operation

1. The control module has an ON/OFF/REMOTE selector

switch that must be set. See Figure 2.3.

OFF Position: Appliance will ignore all power inputs and

will not respond to any commands from a wall switch or

remote. The unit should be in the OFF position during

installation, service, battery installation, fuel conversion,

and in the event that the control goes into LOCK-OUT

mode as a result of an error code.

ON Position: Appliance will ignite and run continuously

in the HI flame setting, with no adjustment in flame

output. This mode of operation is primarily used for

initial installation or power outage operation with battery

backup.

REMOTE Position: Appliance will initiate commands

from an optional wired wall switch and/or the wireless

remote (RC300AU).

2. If using a wired wall switch with the module in REMOTE

mode, the flame output can be adjusted with the HI/

LO selector switch on the module. See Figure 2.3.

Note that the flame HI/LO selector switch will become

inactive once an optional remote control (RC300AU) is

programmed to the control module. Note that the control

module will always ignite the fireplace on HI and remain

so for the initial 10 seconds of operation. If the HI/LO

is switched to the LO position, the flame output will

automatically drop to the lowest setting after the flame

has been established for 10 sec. After this 10 second

period, the flame can be adjusted from HI to LO with

the switch.

3. The control module has safety feature that automatically

shuts down the fireplace after 9 hours of continuous

operation without receiving a command from the

RC300AU remote.

4. If you intend to use both an optional wired wall switch

and the RC300AU remote control to operate your

fireplace, the wall switch will override any commands

given by the remote.

5. The module has the capability to recognize potential

malfunctions. If these occur, it will fail to ignite and/

or respond to a command to ignite via the wall switch

and/or remote. In this case, the module may have

gone into LOCK-OUT mode. In this state, it will emit

a LED error code. To reset the error code, switch the

selector to OFF, and then back to REMOTE or ON. If

the ignition command again fails, the module will emit

an LED error code, prior to going back into LOCK-OUT

mode. Contact your dealer for service if this occurs.

NG/LP GAS-TYPE

SELECTOR SWITCH

SELECTOR

SWITCH

FLAME HI/LOW

SWITCH

STATUS

INDICATOR LED

MODULE

Nine Hour Safety Shutdown Feature
This appliance has a safety feature that automatically

shuts down the fireplace after 9 hours of continu-

ous operation without receiving a command from the

RC300AU remote.