Heat & Glo Fireplace Heat & Glo 350TRSILP-AUF User Manual

Page 22

Advertising
background image

Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. R • 2/13

22

Figure 5.3 Clearances to Combustibles

NOTE: FRAME OPENING HEIGHT IS GREATER THAN PLASTER OPENING HEIGHT.

E

1 in.

(25 mm)

H

G

J

F

I

C

B

D

A

* Adjust framing dimensions for interior sheathing (such as sheetrock)

C** Add 12 in. (305 mm) for rear venting with one 90º elbow.

*

MINIMUM FRAMING DIMENSIONS

Models

A

B

C

D

E

F

G

H

I

J

DVP Pipe SLP Pipe

Rough

Opening

(Height)

**DVP Pipe SLP Pipe

Rough

Opening

(Width)

Clearance

to Ceiling

Combustible

Floor

Combustible

Flooring

Behind

Appliance

Sides of

Appliance

Front of

Appliance

Rough

Opening

(Width)

Rough

Opening

(Width)

Rough

Opening

(Depth)

Rough

Opening

(Depth)

350TRSI-AUF

350TRSILP-AUF

in.

10

8-5/8

32-3/4

16-1/4

16-1/4

34

32

0

0

1/2

1/2

36

mm

254

219

832

413

413

864

813

0

0

13

13

915

Note: The clearance to ceil-

ing is measured from the top

of the unit and it does not

include the standoffs.

Advertising