D. mantel and wall projections – Heat & Glo Fireplace Heat & Glo 350TRSILP-AUF User Manual

Page 23

Advertising
background image

23

Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. R • 2 /13

D. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear-

ances as specified. Framing or finishing material closer than

the minimums listed must be constructed entirely of non-

combustible materials (i.e., steel studs, concrete board, etc).

Combustible Mantels

Combustible Mantel Legs or Wall Projections

Note: All measurements in millimeters.

Note: Measurement is taken from top of the opening,

NOT the top of the fireplace.

Figure 5.5 Clearances to Mantel Legs or Wall Projections

(Acceptable on both sides of opening.)

Figure 5.4 Minimum Vertical and Maximum Horizontal

Dimensions of Combustibles

Figure 5.6 Non-combustible zone

Figure 5.7

76

152

178

203

229

279

305

51

76

102

127

305

279

254

229

203

178

152

51

102 127

254

TOP FRONT EDGE

OF FIREPLACE

NON-COMBUSTIBLE

BOARD

If joints between the finished walls and the heater surround

(top and sides) are sealed, a 149 ºC (300 ºF) minimum seal-

ant material must be used. These joints are not required to

be sealed. Only non-combustible material (using 149 °C

(300 ºF) minimum adhesive, if needed) can be applied as

facing to the heater surround. See Figure 5.7.

FINISH WALL MATERIAL MAY BE

COMBUSTIBLE - TOP AND SIDES

NON-COMBUSTIBLE

BOARD

HIGH TEMPERATURE (149 ºC (300 ºF MIN.)

TOP AND SIDE SEAL JOINT

Note: Zero clearance finishing allowed on sides of surround

and top of non-combustible board.

3 ft. (914 mm) MAXIMUM

TOP VIEW

2-7/8 in.

*

(876 mm)

MINIMUM

1/2 in.

*

(13 mm)

MINIMUM

*

Add 1/2 in. (13 mm for rear vent)

1/2 in. (13 mm)

SHEETROCK

3-1/2 in.

(89 mm)

1/2 in.

(13 mm)

NON-COMBUSTIBLE ZONE

NON-COMBUSTIBLE

BOARD SHIPPED

WITH APPLIANCE