Heat & Glo Fireplace Heat & Glo 350TRSILP-AUF User Manual

Page 25

Advertising
background image

25

Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. R • 2 /13

Figure 6.3 Minimum Clearances for Termination

NOTES:

1. All distances are measured vertically or horizontally along the wall to a point

in line with the nearest part of the terminal.

2. Prohibited area below electricity meter or fuse box extends to ground level.

3. See clause 5.13.6.6 for restrictions on a flue terminal under a roofed area.

4. See Appendix J, Figure J1(a) and J2(a) for clearances required from a flue

terminal to a LP Gas cylinder. A flue terminal is considered to be a source of ignition.

MINIMUM CLEARANCES REQUIRED FOR BALANCED FLUE TERMINALS

OR THE FLUE TERMINALS OF OUTDOOR APPLIANCES

T = Flue terminal

M = Gas meter

Shading indicates prohibited

I = Mechanical air inlet

P = Electricity meter or fuse box

areas for flue terminals

f

c

n

I

openable

window

j

j

j

door

h

h

h

T

e

e

P

T

g

k

k

d

b

d

M

a

c

g

See note 2

See note 3

T

a - Below eaves, balconies or other projections:

MIN. CLEARANCE - in. (mm)

Appliances up to 50 MJ/h input .................................................................................... 12 (300)

Appliances over 50 MJ/h input ...............................................................................20-1/2 (500)

b - From the ground or above a balcony ............................................................................... 12 (300)

c - From a return wall or external corner .........................................................................20-1/2 (500)

d - From a gas meter (M) ...................................................................................................... 39 (1000)

e - From an electricity meter or fuse box (P) ...................................................................20-1/2 (500)

f - From a drain or soil pipe .................................................................................................... 6 (150)

g - Horizontally from any building structure (unless appliance approved

for closer installation) or obstruction facing a terminal ............................................... 20-1/2 (500)

h - From any other flue terminal, cowl, or combustion air intake .................................... 20-1/2 (500)

j - Horizontally from an openable window, door, non-mechanical air

inlet, or any other opening into a building, with the exception of

sub-floor ventilation:

Appliances up to 150 MJ/h input ............................................................................20-1/2 (500)

Appliances over 150 MJ/h input ................................................................................... 60 (1500)

k - From a mechanical air inlet, including a spa blower ....................................................... 60 (1500)

n - Vertically below an openable window, non-mechanical air

inlet or any other opening into a building, with the exception of ...................................... See table

sub-floor ventilation ................................................................................................................ below

CLEARANCE

Space Heaters

All other appliances

Up to 50 MJ/h input

Up to 50 MJ/h input

Over 50 MJ/h input and

Up to 150 MJ/h input

Over 50 MJ/h input

6 in. (150 mm)

20 in. (500 mm)

39 in. (1000 mm)

59 in. (1500 mm)