42

B. Rear Vent

NOTICE: Once appliance is set up for top or rear venting,

it CANNOT be changed at a later time.

NOTICE: Once the seal cap has been removed it CANNOT

be reattached.

Figure 9.8 Fold the tabs toward the center of the fire plug

(90º) and remove the insulation gasket.

Figure 9.9 Cut the metal retaining band and fold the

sides out.

Figure 9.10 Fold the center parts of the retaining band

out and use to remove the seal cap.

Figure 9.11 Discard the seal cap, remove and discard

the insulation basket. Note: Once the seal cap has been

removed it CANNOT be reattached.

Figure 9.12 Attach the first vent section (it will snap into

place). Slide the insulation gasket onto the vent section,

up against the appliance and over the tabs. Use two self-

tapping screws to secure gasket to outer wrap.

Figure 9.7 To attach the first section of vent pipe, make

sure to use the fiberglass gasket to seal between the first

vent component and the outer fireplace wrap. Use 2 self

tapping screws to secure the gasket to the outer wrap.
Note: Once the seal cap has been removed, it cannot be

reattached.