K. assemble and install storm collar, L. install vertical termination cap – Heat & Glo Fireplace Heat & Glo 350TRSILP-AUF User Manual

Page 51

Advertising
background image

51

Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. R • 2 /13

CAULK

K. Assemble and Install Storm Collar

CAUTION! Risk of Cuts, Abrasions or Flying Debris.

Wear protective gloves and safety glasses during instal-

lation. Sheet metal edges are sharp.
• Connect both halves of the storm collar with two screws

(see Figure 10.21).

• Wrap the storm collar around the exposed pipe section

closest to the roof and align brackets. Insert a bolt

(provided) through the brackets and tighten the nut to

complete the storm collar assembly. Make sure the collar

is tight against the pipe section.

• Slide the assembled storm collar down the pipe section

until it rests on the roof flashing (see Figure 10.22).

• Caulk around the top of the storm collar (see Figure 10.23).

Figure 10.21 Assembling the Storm Collar

BRACKETS

Figure 10.22 Assembling the Storm Collar Around the Pipe

Figure 10.20

SCREWS

CAULK

STORM

COLLAR

(1 of 3)

Figure 10.23

TERMINATION CAP

L. Install Vertical Termination Cap

• Locate and mark the flue center point on the underside

of the roof, and drive a nail through the center point.

• Make the outline of the roof hole around the center point

nail.

• The size of the roof hole framing dimensions depend on

the pitch of the roof. There

MUST BE a 1 in. (25 mm)

clearance from the vertical flue pipe to combustible ma-

terials.

• Mark the roof hole accordingly.
• Cover the opening of the installed flue pipes.
• Cut and frame the roof hole.
• Use framing lumber the same size as the roof rafters and

install the frame securely. Flashing anchored to the frame

must withstand heavy winds.

• Continue to install concentric flue sections up through

the roof hole and up past the roof line until you reach the

appropriate distance above the roof.

• Attach the vertical termination cap by sliding the inner

collar of the cap into the inner flue of the pipe section

while placing the outer collar of the cap over the outer

flue of the pipe section.

• Secure the cap by driving three self-tapping screws

(supplied) through the pilot holes in the outer collar of

the cap into the outer flue of the pipe (see Figure 10.23).

Advertising
This manual is related to the following products: