Heat & Glo Fireplace Heat & Glo 350TRSILP-AUF User Manual

Page 53

Advertising
background image

53

Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. R • 2 /13

Figure 11.1

The gas is introduced to the appliance on the left hand

side. See Figure 11.1.
After the gas pipe installation is complete, check carefully

all gas connections for leaks with a commercially-available,

noncorrosive leak check solution. Be sure to rinse off all

leak check solution following testing. DO NOT USE AN

OPEN FLAME.
NOTICE: the gas supply line should be purged of any

trapped air prior to the first firing of the unit.

• Section 16 also shows gas line access.
• Gas line may be run through knockout(s) provided.
• The gap between supply piping and gas access hole

may be caulked with high temperature caulk or stuffed

with non-combustible, unfaced insulation to prevent cold

air infiltration.

• Ensure that gas line does not come in contact with outer

wrap of the appliance. Follow local codes. Reference

AS5601 Gas Installation Standard

• Pipe incoming gas line into valve compartment.
• Connect incoming gas line to the connection on manual

shutoff valve.

WARNING! Risk of Fire or Explosion! Support control

when attaching pipe to prevent bending gas line.
• A small amount of air will be in the gas supply lines.
WARNING! Risk of Fire or Explosion! Gas build-up dur-

ing line purge could ignite.

• Purge should be performed by qualified service

technician.

• Ensure adequate ventilation.

• Ensure there are no ignition sources such as sparks

or open flames.

Light the appliance. It will take a short time for air to purge

from lines. When purging is complete the appliance will

light and operate normally.
WARNING! Risk of Fire, Explosion or Asphyxiation!

Check all fittings and connections with a non-corrosive

commercially available leak-check solution.

DO NOT use

open flame. Fittings and connections could have loos-

ened during shipping and handling.
WARNING! Risk of Fire! DO NOT change valve settings.

This valve has been preset at the factory.

GAS ACCESS

Advertising
This manual is related to the following products: