Motor Wiring Diagram

Automatic Operation Type Output (Single Phase)

Operation

Check the water level before starting the pump.
If the pump is operated continuously for an extended period of time in a dry condition or at
the lowest water level, the motor protector will be activated in single phase units. Constant
repetition of this action will shorten pump service life. Do not start the pump again in such
a situation until after the motor has completely cooled.

SPECIAL NOTICE for Cord Connected Pumps

These pumps are not designed for and CANNOT be installed in locations classified as
hazardous in accordance with the National Electric Code, ANSI/NEPA 70-1984.
• Connection devices shall provide for a watertight connection to the power supply and

provide adequate strain relief for the cord.

• Installation of the box shall be a UL listed watertight connection box used with a UL

listed, liquid-tight fitting suitable for the cord.

• Connection boxes should be sized in accordance with the National Electric Code

specifications and installed as intended for the application.

• All connection devices are to be provided by the installer.
• Only qualified personnel shall service and install the pump.