Troubleshooting Checklist

Problem

Possible Causes

Pump does

not run or

hums

• Line circuit breaker is off, or fuse is blown or loose.

• Water level in the sump has not reached turn-on level as

indicated in the installation drawing.

• Pump cord is not making contact in the receptacle.

• Float is stuck. It should operate freely in the basin.

• Debris may be stuck in the impeller.

• If all of the above are OK, then the motor winding may be open

or the capacitor may be defective.

Pump runs but

does not

deliver water

• Check valve is installed backwards. Arrow on the valve should

point in the direction of flow.

• Discharge shut-off valve (if used) may be closed.

• Pump is air-locked. Start and stop several times by plugging and

unplugging cord. Check for clogged vent hole in pump case.

• Impeller or volute openings are fully or partially clogged.

Remove pump and clean.

• Inlet holes in pump base are clogged. Remove pump and clean

the openings.

• Vertical pumping distance is too high. Reduce distance or resize

pump.

Pump runs
and pumps out
sump, but
does not stop

• Float is stuck in the up position. Be sure the float operates freely

in the basin.

• Defective float switch.

Pump runs but
delivers only a
small amount
of water

• Pump is air-locked. Start and stop several times by plugging and

unplugging the cord.

• Check for a clogged vent hole in the pump case.

• Vertical pumping distance is too high. Reduce the distance or

resize the pump.

• Inlet holes in pump base are clogged. Remove pump and clean

the openings.

• Impeller or volute openings are fully or partially clogged.

Remove the pump and clean.

Fuse blows or
circuit breaker
trips when
pump starts

• Pump impeller is partially clogged, causing motor to run slow

and overload. Remove pump and clean.

• Motor stator may be defective.

• Fuse size or circuit breaker may be too small. Must be 15 amps.

• Impeller or volute openings are fully or partially clogged.

Remove pump and clean.

• Water lead inside the pump motor.