Basin and cover, Maintenance tips, Safety information and introduction – HONDA Submersible Pump WSP33AA User Manual

Page 7: B warning, B caution

Advertising
background image

5

Basin and Cover

The basin should not be less than 18 inches in diameter and 24 inches deep. Larger
diameters are advisable in instances of increased pump capacity requirements:

The basin should be located such that all water flows into the basin due to gravity.
Outdoor installations should be at a sufficient depth to ensure protection from freezing.

Maintenance Tips
• Every three or four months:

1) Clean the pump screen or inlet opening. If your sump collects the discharge from an

automatic washing machine, cleaning will be required more often. (Before removing
the pump, be sure to disconnect the unit from electrical power; and reconnect after
completion of cleaning).

2) Pour enough water into the sump to cycle the pump and assure its proper

functioning.

• Annually:

Remove and clean the pump. Clean the sump pit also.

Safety Information and Introduction

Required Pump Capacity

Minimum Basin Diameter

Up to 35 GPM

18"

Over 35 GPM

24"

Over 60 GPM

30"

Over 100 GPM

36"

Over 150 GPM

48"

B WARNING

Before handling this pump, always disconnect The power

first.

This pump should only be serviced by a qualified person or a factory

trained person.

B CAUTION

This instruction manual includes necessary items for installation, operation, and

maintenance. Read this manual carefully to ensure correct installation, operation, and

maintenance. Be sure to keep this instruction manual on hand for future reference

Advertising
This manual is related to the following products: