Setting And Using The Appliance Control (cont.)

6.00

.

Push the NEXT button to step to the next parameter. The display will show: Hard. Gr. 040 The 040 is the
hardness number of the water tested. This number is to be the actual hardness reading and is not
compensated for iron.

6,OOa

Push and release the SELECT DIGIT button until the cursor ( )

is

positioned in the display as follows:

Hard. Gr. Q40. The cursor is now under the "ten" position.

6.00b

Continue pushing the SELECT and CHANGE buttons until the desired hardness number is displayed.
Example: Hard. Gr. 025

L

Push the NEXT button to step to the next parameter. The display will show: Iron ppm 00

This parameter is used to calculate a compensated hardness automatically.

7.00a

Push the SELECT and CHANGE buttons until the desired iron number is displayed.
Example: Iron ppm 02

8.00

Push the NEXT button to step to the next parameter. The display will show: Mang. ppm 00

8.00a

Push the SELECT and CHANGE buttons until the desired manganese number is displayed.

Example: Mang. ppm QO

8.00b

Push the NEXT button to step to the next parameter. The display will show: SALT = Sodium.
WARNING!
When iron and/or manganese is present in the water supply, we do not recommend using potassium
chloride as a regenerant. Iron and/or manganese bacteria may develop and foul the conditioning media and may
void the warranty.

8.00c

Push the SELECT and CHANGE buttons until the desired regenerant is selected. EXAMPLE: Salt = Sodium.

9,00

Push the NEXT button to step to the next parameter. The display will show: Comp. Hard. 00033

This parameter is the calculated compensated hardness using the hardness, iron and manganese settings.
The formula is (4 x each ppm iron) + (4 x each ppm manganese) + hardness = compensated hardness.
This is not a parameter that can be set. The display should now read: Comp. Hard. 00033

10.00

Push the NEXT button to step to the next parameter. The display will show: Capty. Gr. 28730
This parameter is used to set the softening capacity of the appliance. (See WaterMax engineering specifications
or setting charts for capacities based on salt usage.)

10.00a Push the SELECT and CHANGE buttons until the desired capacity number is displayed.

In this example, set to: Capac. Gr. 28730

11.00

Push the NEXT button to step to the next parameter. The display will show: 72-96hr Regen Yes
This parameter, if set to "Yes", is used to force the appliance to regenerate every 96 hours if regularly scheduled
regenerations based on water usage do not occur in 96 hours or less intervals. This should always be "yes" if iron
is present in the water.

11.00a

Push CHANGE button to toggle parameter value from "No" to "Yes". In this example, set to: 96hr Regen Yes

12.00

Push the NEXT button to step to the next parameter. The display will show: Distill/RO Yes
Set this parameter to "Yes" if a distiller or reverse osmosis system is plumbed to use soft water from
the WaterMax.

12.00a Push the CHANGE button to toggle parameter value from "No" to "Yes". In this example, set to: Distill/RO Yes

13.0

Push the NEXT button to step to the next parameter. The display will show: Backwash 1 Q1.0
(See WaterMax setting chart.) The "01.0" is the time, in minutes to the nearest tenth, for which the first backwash
cycle can be set.

13.00a

Push the SELECT and CHANGE buttons until the desired backwash time is displayed.
In this example, set to: Backwash 1 07.0