F4,11gineering Specifications

60 SERIES

63MAQ 63BEQ* 63MXQ

63MDQ 62AMQ **62APQ*** 62AKQ 62AJQ****

Tannin (ppm)

0

0

0

0-2

0

0

0

0

Sulfur (ppm) - SulfurStat

0

0

0

0

0

0-5**

0

0

Iron (ppm) - ferrous - clear water •

0

0

12

0

12

2-12**

15

5

Maximum Compensated Hardness

90

90

110

90tt

90

90

90

60

Maximum Chlorine (ppm)

1

3

0

0

0

0

0

0

Minimum pH

NA

NA

7

7

7

7

7

6.3

Filtration - nominal rating (microns)

20

25

20

20

20

20

20

20

#1 Salt - 5850 grains per lb of salt (Ibs./capacity)

1/5,850

1/5,850

1.6/9,360

NA

1/5,850

NA

NA

NA

#2 Salt - 5163 grains per lb of salt (Ibs./capacity)

2.7/13,890 2.7/13,890 4.2 /21,680

NA

2.7/13,890

NA

NA

2.7/13,890

#3 Salt - 4679 grains per lb of salt (Ibs./capacity)

6.2/28,730 6.2/28,730

9.6/44,840

8.5/28,730

6.2/28,730 6.2/28,730

6.2/28,730 6.2/28,730

#4 Salt - 3828 grains per lb of salt (Ibs./capacity)

9.3/35,300 9.3/35,300 14.4/55,090 10.7/35,300

9.3/35,300 9.3/35,300

9.3/35,300 9.3/35,300

Media Amount Compartment #1

1.5 lbs.

2.0 lbs.

1.5 lbs.

1.5 lbs.

NA

NA

NA

NA

Media Amount Compartment #2

Empty

.4 cu.ft.

.6 cu.ft.

.3 cu.ft.

6 Ibs.

27 Ibs.

.4 cuft.

.4

cu.ft.

Media Amount Compartment #3

1.06 cu.ft.

1.06

cu.ft.

1.06 cu.ft.

1.06 cu.ft

1.06

cuff.

1.06 cu.ft.

1.06

cuff.

1.06 cu.ft.

Drain Line Flow Control (gpm)@ min. water presure

2.41'

3t

2.4t

2.4t

5t

Empty***t

7t

7t

Brine Line Flow Control Refill (gpm)

.5

.5

.5

.5

.5

.5

.5

.5

Water Pressure (min-max psi)

20-120

20-120

20-120

20-120

20-120

30-120

30-120

30-120

Flow Rate @ 25 psi drop

19.5

19.5

17

17

23

19.6

19.6

20.5

Flow Rate @ 15 psi drop#

11

13

10.5

10.5

11.2

10.6

10.6

12.5

Pressure Drop @ Flow Rate Of 4 gpm

6.5 psi

8.5 psi

8.5 psi

8.5 psi

3.2 psi

6 psi

6 psi

7 psi

(#1 Salt setting) total length of reg. Min / gal

12/13.5

12/16

12/13.5

NA

12/24

NA

NA

NA

(#2 Salt setting) total length of reg. Min / gal

18/16.5

18/19

26/20.5

NA

18/27

NA

NA

23/70

(#3 Salt setting) total length of reg. Min / gal

38/26.5

38/29.5

58/36.5

47/31

38/37

44/80

44/80

44/80

(#4 Salt setting) total length of reg. Min / gal

56/35.5

56/38

74/44.5

64/39.5

58/56

61/89

61/89

61/89

Shipping weight (Ibs.)

135

152

168

152

140

167

160

180

Bacteriostatic - KDF® Process Media - Listed

With The U.S. EPA As A Bacteriostatic Device.

U.S. EPA #54369-OH-001

YES

YES

YES

YES

YES

YES

YES

YES

Valve Inlet/Outlet 1"

Drain Line (Minimum ID.)

%Y "

Water Temperature (Min-Max) 40-120 °F

Height (inches) 38-1/4"

Floor Space (inches) 15" x 30"

Salt storage capacity: 200 Ibs, 90kg

Brine & Rinse total: .65 gpm

Brine Draw: .25 gpm

Rinse: .4 gpm

Electrical rating: 115V, 60 cycle.
Iron Reduction To .3 ppm Or Less.

When Adding Media In The Field, Check For Proper Settings

(See Specifications, Above.)

Regeneration Every 96 Hours Is Required When Iron Is

Present In The Raw Water Supply. Use Salt Setting #3 Or #4.

*Municipally Supplied Chlorinated Water Only.

**Must Have A Minimum of 2 ppm Iron and a Minimum

of 200 ppm TDS.

***This model Has No Backwash Flow Control Button Or

Retainer. Must Have A Minimum Of 7 gpm @ 30 psi

Available For Proper Backwash.

****Calcite Will Add Additional Hardness To Water Before

Softening.

tRate Of Flow Must Be Verified At The End Of

%Y

"

ID

Drain Line.

tt

An

y Hardness Over 10 gpg Will Increase The Chance

Of Calcium Carbonate Precipitation. As The

Hardness Increases So Does The Chance Of This

Precipitation. Must Use Citric Acid to Regenerate

Along With Salt.