Mode i setting chart, 60 series, 1 salt setting – Hague Quality Water Intl 63MAQ User Manual

Page 14: 2 salt setting, 3 salt setting, 4 salt setting

Advertising
background image

Mode I Setting Chart

60 SERIES

63MAQ

63BEQ

*

63MXQ

63MDQ

62AMQ

62APQ

** ***

62AKQ

62AJQ

****

Mode1

YES

YES

YES

YES

YES

YES

YES

YES

Regeneration
Frequency

As

required

As

required

As

required

1 or 2

As

required

1 or 2

1 or 2

1 or 2

96 hour regeneration
(if iron present – yes)

--

YES

--

YES

YES

YES

YES

#1 SALT SETTING

Backwash 1 (minutes)

1

1

1

2 •

--

Brine rinse (minutes)

7

7

7

7

--

---

–'

Backwash 2 (minutes)

3

3

3

2

---

--

---

Capacity
t . salt lbs.

5,850

1

lb.

5,850

1 lb,

9,360

1.6 lb.

5,850

1 lb.

--

--

#2 SALT SETTING

Backwash 1 (minutes)

1

1

1

S

-

2

--

7 S

Brine rinse (minutes)

12

12

19

12

---

--

12

Backwash 2 (minutes)

3

3

3

2

---

--

2

Capacity

0. salt Ibs.

13,890

2.7 lbs.

13,890

2.7 lbs.

21,680

4.2 lbs.

13,890

2.7 Ibs,

--

13,890

2.7 lbs.

#3 SALT SETTING

Backwash 1 (minutes)

1

1

1tt

1

2tt

7

7

7

Brine rinse (minutes)

30

30

47

38

30

30

30

30

Backwash 2 (minutes)

3

3

3

3

2

2

2

2

Capacity

0. salt lbs.

28,730

6.2 lbs.

28,730

6.2 lbs.

44,840
9.6
Ibs.

28,730
8.5 Ibs.

28,730
6.2 lbs.

28,730

6.2 lbs.

28,730
6.2 Ibs.

28,730

6.2 Ibs.

#4 SALT SETTING

Backwash 1 (minutes)

1

1

Itt

1

4tt

7

7

7

Brine rinse (minutes)

45

45

60

52

45

45

45

45

Backwash 2 (minutes)

3

3

3

3

2

2

2

2

Capacity
LDsalt Ibs.

35,000
9.3 Ibs.

35,000
9.3 Ibs.

55,090

14.4 Ibs.

35,000

10.7 Ibs.

35,000

9.3 lbs.

35,000

9.3 Ibs.

35,000

9.3 lbs.

35,000

9.3 Ibs.

*Municipally supplied chlorinated water only.
**Must have a minimum of 2 ppm iron and a minimum of 200 ppm TDS. See Engineering Specifications.
***Unit has no backwash flow control button or retainer. Must have a minimum of 7 gpm@30 psi available for proper backwash.
****Calcite will add additional hardness to water before softening.
'If iron is present in water supply, use salt setting #3 or #4.
ttlf iron is present in the water supply, set #1 backwash to 7 minutes.