Venting, Venting with 8” x 5” pipe, Rear vent model – Harman Stove Company HB 38 DV User Manual

Page 21

Advertising
background image

VENTING

Only For Qualified Installers

21

Maximum of four 45

0

elbows allowed.

Subtract three feet of total horizontal pipe
length for each of the 3rd and 4th 45

0

elbows

used.

Maximum of two 90

0

elbows allowed.

Subtract five feet of total horizontal pipe
length for second elbow.

Venting with 8” x 5” Pipe

A combination of one 90

0

elbow and two 45

0

elbows is allowed.
Subtract three feet of total horizontal pipe
length for each 45

0

elbow used.

Vent termination m us t remain
within the shaded area regardless of
configuration.

This appliance must not be
connected to a chimney flue
serving a separate solid fuel
burning appliance.

Maximum horizontal rear
v ent run is 2 4 inches .
Vertical venting of the
rear vent model is not
approved. Nev er us ed
6 5/8” x 4” pipe for rear
vent.

Rear Vent Model

Advertising