Venting, Venting with 6, X 4” pipe – Harman Stove Company HB 38 DV User Manual

Page 22

Advertising
background image

VENTING

Only For Qualified Installers

22

Maximum of four 45

0

elbows allowed.

Subtract three feet of total horizontal pipe
length for the 3rd and 4th 45

0

elbow used.

Maximum of two 90

0

elbows allowed.

Subtract five feet of total horizontal pipe
length for second elbow.

Venting with 6

5

/

8

” x 4” Pipe

A combination of one 90

0

elbow and two 45

0

elbows is allowed.
Subtract three feet of total horizontal pipe
length for each 45

0

elbow used.

Vent termination m us t remain
within the shaded area regardless of
configuration.

Use Adaptor (Part No. 1222D )
to reduce to 6

5

/

8

x 4 vent pipe.

For the Serenity Direct Vent Fireplace, the vent/

air intake termination clearances above the high side
of an angled roof are as follows:

Roof Pitch

Feet

Meters

Flat to 6/12

1

0.3

7/12 to 9/12

2

0.6

10/12 to 12/124

1.2

13/12 to 16/126

1.8

17/12 to 21/128

2.4

Advertising