C7189U REMOTE INDOOR SENSOR

3

69-1710EFS-1

WIRING

The sensor can be used to provide one remote sensor (see Fig. 6) or as a temperature averaging network with multiple
sensors connected (see Fig. 7). The thermostat is not part of the average network.

CAUTION

ELECTRICAL HAZARD.
Can cause electrical shock or equipment damage. Disconnect power before wiring.

1. Run the wire cable from the thermostat to the

remote sensor location.

2. Loosen screw terminals, insert wires into terminal

block (polarity does not matter), then retighten
screws.

3. Push excess wire back into the wall opening.
4. Plug the wall opening with non-flammable insulation

to prevent drafts from affecting the sensor operation
and replace the cover on the remote sensor.

5. Connect the two wires to the thermostat's remote

sensor terminals (polarity does not matter) and
replace the thermostat back onto the wallplate. See
Fig. 6.

Fig. 5. Terminal block wiring.

Fig. 6. Wiring a single C7189U Sensor.

Fig. 7. Wiring Multiple C7189U Sensors.

OPERATION

Once a remote indoor temperature sensor is connected to
the thermostat, the thermostat's sensor is no longer used.
The thermostat's installer setup should be modified to tell
the thermostat that remote indoor temperature sensor(s)
have been used. The Inside temperature reading on the
thermostat's display will be the remote sensor(s)
temperature location(s). See Fig. 8.

.

Fig. 8. Inside Temperature Reading on TH8000 Series

Thermostat.

M24116

2

C7189

RC

R

W

Y

G

C

Y2

W2

S2

S1

M19972A

R

C

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND

OVERLOAD PROTECTION AS REQUIRED.

IF MORE THAN ONE C7189 REMOTE SENSOR IS REQUIRED,

REFER TO FIGURE 7.

WIRES MUST HAVE A CABLE SEPARATE FROM THE

THERMOSTAT CABLE.

1

1

3

2

3

M19973

SENSORS MUST BE ARRANGED IN THIS
CONFIGURATION TO OPERATE CORRECTLY.

WIRES MUST HAVE A CABLE SEPARATE FROM THE
THERMOSTAT CABLE.

1

2

Y2

W2

S2

1

1

2

C7189

C7189

C7189

C7189

Y2

W2

2

1

1

2

C7189

C7189

C7189

C7189

C7189

C7189

C7189

C7189

C7189

Heat On

SCHED

HOLD

CLOCK SCREEN

MORE

TUE

AM

FAN

AUTO

SYSTEM

HEAT

CHANGE FILTER UV LAMP HUMIDIFIER PAD

Following

Schedule

Inside

Set To

M19974

Advertising