Configuration and electrical connection

17

Use only cables with wire diameters up to 1.5 mm

2

. We rec-

ommend the cable type JE-Y(St)Y 2

Ч2Ч0.8. Use the accom-

panying connector types and cables of sufficient length.

1. Connector (1 to 12)
2. Connections for expan-

sion module HCS 60

3. Antenna

connector

4. Connector of actuator for

zones 1 through 8

In general, each zone can control up to 3 actuators. 3 actuators can
be connected for zone 1 and one each for zones 2 through 5. One
connection for the expansion module is available for each of the
zones 6 through 8.

The prefabricated cable of the thermal actuators can be
extended from 1 to 3 meters. This cable is available plug-in-
ready as type HCV 2.