Assigning zones and issuing room names

37

Assigning setpoint adjusters of type HCW 23 to a zone

Setpoint adjusters of type HCW 23 have a fixed allocation to zones 1
and 2 due to their wiring.

If the remote controller HCW 23 is removed, the assignment
has to be removed as well. "Refer to "Canceling assignment"
on Page 38.

Assigning room names for cooling function

If the cooling function is activated (see Page 30), 2 room names can
be assigned for each temperature zone. Example: "Heating living",
"Cooling living". The time programs and setpoint values are activated
by the heating or cooling input signal.

Switch closed
(terminals 1 and 3)

Cooling active

Switch open
(terminals 1 and 3)

Heating active

Assigning 2 room names to a temperature zone

Enter room name in zoning plan.

Press Installation button .
The LED of zone 1 flashes red.

Assign next setpoint adjuster.

Continue when you have assigned the next setpoint adjuster: