Honeywell HCE 60 User Manual

Page 45

Advertising
background image

Assigning zones and issuing room names

43

The colors of LEDs 1 through 8 now provide information on a fault in
the temperature zones:

Off

No fault

Red

Cable break / no connection to setpoint adjuster

Green

No connection to Hometronic Manager resp. wireless
setpoint adjuster HCU 30

Orange

No connection to setpoint adjuster and Hometronic Man-
ager

The storey controller exits the fault display after approx. 60 seconds
and returns to normal mode.

Completing start-up

Closing setpoint adjuster

Replace cover and snap in both snap locks.

Handing over zoning plan

Hand over the completed zoning plan and the installation instructions
to the customer. Both documents are important, as changes to the
system may be made in future.