Storm water samplers are equipped with a special prerinse that occurs
only with the first sample collection. This “one time only” rinse ensures a
clean intake for installations that may remain dormant for extended
periods, and extends battery life by eliminating the prerinse for
subsequent samples.

16-A. Highlight Storm Water using the

UP

and

DOWN

keys on the Advanced

Sampling Menu. Press

SELECT

to continue.

16-B. Enable or Disable Storm Water using the

CHANGE CHOICE

key. Press

ACCEPT

to continue.

16-C. Select a Start Condition using the

CHANGE CHOICE

key.

Rain

Level

Rain or Level (either conditions must be met for the program to begin)

Rain and Level (both conditions must be met for the program
to begin)

Immediate (program starts as soon as the

RUN

key is pressed, a start

condition is not required)

External Trigger (program starts when signaled by an external device
at least 61 seconds through the Auxiliary connector. No start
condition is required).

16-D. Enter the Start Condition Limits. Rainfall times will depend on the

historical rainfall in a specific area. Consult your state or an EPA
regional office for details.

First Flush Bottles
First flush describes the initial storm water runoff. This runoff may contain
higher concentrations of pollutants and is sequestered in separate bottles
from the flow or time-weighted composite samples.

a.

Enter the number of bottles to set aside for the First Flush portion of
the sampling program using the numeric keypad.

11:00 AM 21 - APR - 01

ADVANCED SAMPLING

SELECT

SETPOINT SAMPLING
SPECIAL PUTPUT
START/STOP TIMES

STORM WATER

RETURN

TIMED BOTTLE SETS
UPSET SAMPLE

Table 4 Start Condition Requirements

Rain

Enter the amount of rainfall and the time period when it must fall.

Level

Level Limit

Rain and Level

Enter the amount of rainfall and the time period when it must fall, and desired level limit.