User menu structure – Honeywell RESET CONTROLS AQ251 User Manual

Page 8

Advertising
background image

AQUATROL ZONE SYNCHRONIZING BOILER RESET CONTROLS

Automation and Control Solutions
Honeywell International Inc.

Honeywell Limited-Honeywell Limitée

1985 Douglas Drive North

35 Dynamic Drive

Golden Valley, MN 55422

Toronto, Ontario M1V 4Z9

customer.honeywell.com

® U.S. Registered Trademark
© 2009 Honeywell International Inc.
69-1979—04 M.S. Rev. 09-09

USER MENU STRUCTURE

Press the Menu button on the keypad to display the User Menu. Fig. 3 illustrates all possible User Menu selections.

Fig. 3. User Menu Structure.

AQUATROL® is a registered trademark of Honeywell International Inc.

M27750

BOILER UNITS: °F

ZONE UNITS: °F

TIME DISP: 12H

D.S.T.: ENABLE

YEAR: 2008

MONTH: JAN

DATE: 1

DAY: MONDAY

TIME: 12:00A

HOMEPAGE: DETAIL

BACKLIGHT: AUTO

POWER FAILURE

NOTICE: BACKLIGHT

PREFERENCES / TIME

SYSTEM STATUS

PREFERENCES/TIME

ZONE SETTINGS

PROGRAM SETTINGS

STATISTICS

USER MENU

AUX IN EM.SHUT

BOILER: IDLE

CALL FOR DHW

CALL FOR HEAT

DHW DISABLE

LOST ZONE A-1

...

LOST ZONE D-16

NO DHW PROBE

NO OUTDOOR PROBE

NO RETURN PROBE

NO SUPPLY PROBE

SHORT CYCLE PROT

VALVE INIT

WATER READY

WWSD ACTIVE

SYSTEM STATUS

1

ZONE A-1

ROOM TEMP

FLOOR TEMP

SETPOINT: 70

FLOOR SETPT: 70

HEAT/COOL STATUS

SETBACK: 7

SETPOINT MAX: 100

SETPOINT MIN: 41

FLOOR LIM HI: 100

FLOOR LIM LO: 41

SETPOINT VACANCY

HEAT: 41

SETPOINT VACANCY

COOL: 100

CHANGEOVER: 2

KEYBOARD: UNLOCK

ZONE SETTINGS (All or Single)

2

ARE YOU SURE?

NO YES

MON WAKE 6:00A

MON LEAVE 8:00A

MON RETRN 4:30P

MON SLEEP 10:00P

...

SUN WAKE 6:00A

SUN LEAVE --:--

SUN RETRN --:--

SUN SLEEP 10:00P

ALL WAKE 6:00A

ALL LEAVE 8:00A

ALL RETRN 4:30P

ALL SLEEP 10:00P

COPY TO ALL DAYS

COPY WAKE

COPY LEAVE

COPY RETRN

COPY SLEEP

MODE: AUTO

EDIT ALL DAYS

EDIT DAILY

PROGRAM SETTINGS

EDIT ALL DAYS

EDIT DAILY

LAST DATA RESET: 2000 JAN 01

BOILER FIRE ACTIV: 0H

BOILER PUMP ACTIV: 0H

DHW PUMP ACTIV: 0H

AUX PUMP ACTIV: 0H

AUX OUT ACTIV: 0H

ZONE A-1

ACTIV: 0H

STATISTICS

3

4

5

1

THE SYMBOLS INDICATE ADDITIONAL SELECTIONS ARE POSSIBLE.
THE FACTORY DEFAULT VALUES ARE SHOWN.

TEMPERATURE VALUES ARE SHOWN IN DEGREES FAHRENHEIT,

WHICH IS THE FACTORY DEFAULT TEMPERATURE UNIT.

EITHER HEAT OR COOL DISPLAYS DEPENDING ON THE SYSTEM’S STATUS.

FACTORY DEFAULT TIMES FOR MON THROUGH FRI.

FACTORY DEFAULT TIMES FOR SAT AND SUN.

2

3

4

5

EDIT ALL ZONES

EDIT SINGLE ZONE

ARE YOU SURE?

NO YES

Advertising