HR150 AND HR200 Perfect Window™ FRESH AIR VENTILATION SYSTEMS

69-0994—4

8

CORE
Clean the core twice each year.

1. Open the access door and carefully grip the ends of the core and pull evenly out-

ward. The core can be snug, but it will slide out of the cabinet.

NOTE: Do not handle the fins because damage can occur.

2. Once out of the cabinet, remove the filters (refer to Air Filter Maintenance sec-

tion).

3. Wash the core in warm soapy water—do not use a dishwasher.
4. Reinstall the clean filters.

5. Reinstall the clean core.

NOTE: Do not detach the foam on the ends of the core or the core label, water does

not damage them.

To install the clean core:

1. First mount the bottom core guide into the bottom H channel.

2. Mount either side core guide, followed by the other side.
3. Mount the top core guide into the top H channel.

4. With all four comers in place and the core straight and even, push on the core

center until the core slides to the back of the cabinet.

NOTE: The core will appear to stick out from the cabinet approximately 1/8 in.

(3mm). It is designed this way, so that the access door will fit tightly against
the core.

MANUAL CONTROL MODEL

FILTER

FILTER CLIP

CORE GUIDE

M11702A