Installation, Mounting a lens, When auto-iris lens is used – Honeywell GC-715P24 User Manual

Page 5: Connection of ac power supply

Advertising
background image

Installation

Mounting a Lens

1. Remove the protective cap in front of the camera.
2. Confirm the mount ring whether it is for C or CS. * Caution1
3. Attach the lens to the lens mount ring.
4. If the lens has an Auto Iris mechanism, connect the iris cable to the Lens connector

(EE/VSD S/W must be set to VSD on the side of the camera)
A. In the case of having no iris amplifier : Set the slide switch to DC (Down side)
B. In the case of having iris amplifier : Set the slide switch VSD (Upper side)
C. Set the S/W on the side of the camera to DC or VSD, too.

If using lens that has iris amplifier, “LEVEL” and “ALC” volume of lens must be

adjust carefully. It may cause any hunting.

When connecting Auto iris lens, be sure to use the connector to be recommended

by manufacturer. (E4-191, Chuo Musen, Japan)

* Caution 1 : This appliance is set to CS mount default.

If you want to use C mount lens, fix a C adapter ring additionally packed
in the box.

5

5

When Auto-Iris Lens is used...

VSD LENS PIN CONFIGURATION

1

2

3

4

①③

1. POWER(12V) 2. NO CONNECTION

3. VIDEO SIGNAL 4. GND

Set the select switch to VSD

DC IRIS LENS PIN CONFIGURATION

1

2

3

4

①③

1. CONTROL-

2. CONTROL+

3. DRIVE+ 4. DRIVE-

Set the select switch to DC

* For the best condition, read lens manual carefully .
* After connecting Auto iris-lens you may need to set flange back focus.

Connection of AC power supply

Must be checked the power source from the external power supply before power on.

Recommended power source capacity :

AC 24V, more than 500mA

6

6

Advertising
This manual is related to the following products: