Caution, Installer system-test – Honeywell DELUXEHEATPUMP T8511G User Manual

Page 6

Advertising
background image

69-1052—1

6

T8511G DELUXE HEAT PUMP ZONE THERMOSTAT

IMPORTANT

Review the settings to confirm that they match
the system. To exit the Installer Setup, press and
hold the Information

i

key until the display

returns to normal (approximately three seconds).

INSTALLER SYSTEM-TEST

Use the Installer System-Test to check the thermostat
operation. Refer to Table 3 for a list of the available
system-tests.

To start the system-test:

CAUTION

The minimum off time for compressors is bypassed
during the Installer System-Test. Equipment damage
can occur if the compressor is cycled too quickly.

Press and hold the increase

and decrease

keys at

the same time, until two zeros appear. All segments of the
LCD will be displayed before the two zeros appear. See
Fig. 11 and 12.

Table 3. Tests Available In the Installer System-Test.

Fig. 11. Display of all the segments of the LCD.

Fig. 12. Display of test number.

Refer to Table 4 for the directions and results of the
specific tests.

NOTE:

Press and hold the increase

and decrease

keys together for three seconds to exit the
system-test. The system-test will time out after
ten minutes without any key presses.

Table 4. Installer System-Test Options.

(Continued)

Em HeatOffCool Auto Only

Heat Cool

OnAuto

System

Fan

Room

Outdoor

Em Ht Temporary Setting

Wait

%Humid

Aux Ht

Remote

Repl

Batt

M4844

M6792

TEST MODE NUMBER

Test

Number

System-Test Description

10-19

Heating equipment can be turned on
and off

20-29

Emergency heat (select models)
equipment can be turned on and off

30-39

Cooling equipment can be turned on
and off

40-49

Fan equipment can be turned on and off

60-69

Keyboard keys test

70-79

Thermostat information including date
code and software versions are displayed

Key to

Press

Test

Number

Description

Heating Equipment System-Test

i

10

Enter heating equipment system-test.

11

Stage-one heat comes on. System fan is also energized.

12

Stage-two heat comes on. Stage-one heat and system fan remain on.

11

Stage-two heat turns off.

10

Stage-one heat and system fan turn off.

Emergency Heating Equipment System-Test (select models)

i

20

Changing from heating to emergency heating equipment system-test.

21

Emergency heat comes on. System fan also comes on.

20

Emergency heat turns off.

Cooling Equipment System-Test

i

30

Change from heating or emergency heating to cooling equipment system-test.

31

Cool and system fan come on.

30

Cool and system fan turn off.

Advertising