5.0 RECOMMENDED OPERATING

PROCEDURES

Ignite the fire in the fireplace with the variable speed control
switch in an "ON" position. The fan will automatically turn
on when the temperature sensor switch closes at approxi-
mately 110

O

F. Heated air should be delivered at the outlet

grille. The fan will continue to operate after the fireplace is
turned OFF until the sensor switch opens.

Various conditions (such as fireplace model, type of fire-
place installation, outside air temperature vs. inside air tem-
perature) can contribute to the length of the time the blower
remains on after the fireplace is turned OFF. The blower can
be turned off manually with the speed control switch.

WARNING: NEVER CONTACT BLOWER WHEEL (VANES)
DURING BLOWER OPERATION.

6.0 MAINTENANCE

Periodically check the fireplace grilles and remove any dust,
dirt or obstructions.

7.0 REPLACEMENT PARTS AND CUSTOMER

SERVICE

Replacement parts and service may be obtained through
your dealer.

Hardware Bag: SRV107-570A

FIGURE 5 Fan Wiring Diagram

NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED
WITH THE APPLIANCE MUST BE REPLACED, IT MUST
BE REPLACED WITH TYPE 105

O

C RATED WIRE.

BLOWER

BLOWER RECEPTACLE

BLK

WHT

WHT

GROUND

GRN

110-120 VAC

WHT

BLK

BLK

JUNCTION BOX

BLK

TEMPERATURE

SENSOR SWITCH

BLK

BLK

BLK

BLK

VARIABLE SPEED

SWITCH

GROUND

WIRE

METAL STYLE JUNCTION BOX

POWER STRIP STYLE JUNCTION BOX

BLUE

VARIABLE

SPEED SWITCH

TEMPERATURE

SENSOR SWITCH

JUNCTION BOX

NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED
WITH THE APPLIANCE MUST BE REPLACED, IT MUST
BE REPLACED WITH TYPE 105

O

C RATED WIRE.

Advertising