Controls and adjustments, A) default dip switch settings, B) harvest control – thermistor – Hoshizaki MODULAR CRESCENT CUBER KM-650MWH User Manual

Page 19

Advertising
background image

19

3. Controls and Adjustments

a) Default Dip Switch Settings

The dip switch is factory-adjusted to the following positions:

Dip Switch No.

1

2

3

4

5

6

7

8

9

10

KM-650MAH

OFF OFF OFF OFF ON ON OFF OFF OFF OFF

KM-650MWH

OFF OFF OFF OFF ON ON OFF OFF OFF OFF

KM-650MRH

OFF OFF OFF OFF ON ON OFF OFF ON OFF

Freeze Timer (9 & 10)

Pump-Out Frequency Control (5 & 6)

Pump-Out Timer (3 & 4)

Harvest Timer (1 & 2)

Normally in the OFF position.

b) Harvest Control – Thermistor

A thermistor (semiconductor) is used for a harvest control sensor. The resistance varies
depending on the suction line temperatures. The thermistor detects the temperature of
the evaporator outlet to start the harvest timer. No adjustment is required. If necessary,
check for resistance between thermistor leads, and visually check the thermistor
mounting, located on the suction line next to the evaporator outlet.

Temperature (°F) Temperature (°C) Resistance (kΩ)

0

-18

14.401

10

-12

10.613

32

0

6.000

50

10

3.871

70

21

2.474

90

32

1.633

Check a thermistor for resistance by using the following procedure:

1) Disconnect the connector K3 on the board.
2) Remove the thermistor. See "V.K. Removal and Replacement of Thermistor."
3) Immerse the thermistor sensor portion in a glass containing ice and water for 2 or 3

minutes.

4) Check for a resistance between thermistor leads. Normal reading is within 3.5 to 7 kΩ.

Replace the thermistor if it exceeds the normal reading.