Km-650mwh (water-cooled) – Hoshizaki MODULAR CRESCENT CUBER KM-650MWH User Manual

Page 29

Advertising
background image

29

PERFORMANCE DATA NO. 06A020

ISSUED: 10/10/2006

ITEM: HOSHIZAKI MODULAR CRESCENT CUBER
MODEL: KM-650MWH

70/21

680

308

675

306

626

284

80/27

676

307

668

303

595

270

90/32

675

306

662

300

598

271

lbs./day kg./day

100/38

651

295

647

294

540

245

70/21
80/27
90/32

watts

100/38

70/21

662

2.51

729

2.76

1173

4.44

80/27

713

2.70

817

3.09

1457

5.52

90/32

729

2.76

890

3.37

1457

5.52

gal./day m

3

/day

100/38

980

3.71

1023

3.87

1977

7.49

70/21

80/27
90/32

min.

100/38

70/21
80/27

90/32

min.

100/38

70/21

231

16.2

231

16.2

238

16.7

80/27

231

16.2

231

16.2

242

17.0

90/32

231

16.2

231

16.2

240

16.9

PSIG kg/cm

2

G

100/38

235

16.5

233

16.4

249

17.5

70/21

50

3.5

51

3.6

53

3.7

80/27

51

3.6

54

3.8

54

3.8

90/32

51

3.6

56

3.9

56

4.0

PSIG kg/cm

2

G

100/38

51

3.6

56

3.9

57

4.0

TOTAL HEAT OF REJECTION FROM COMPRESSOR

1,400 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

WATER FLOW FOR CONDENSER

77 gal./h [AT 100ºF (38ºC) / WT 90ºF (32ºC)]

PRESSURE DROP OF COOLING WATER LINE

less than 10 PSIG

Note: Pressure data is recorded at 5 minutes into freezing cycle.
The data not in

bold

should be used for reference only.

2.1

TOTAL HEAT OF REJECTION FROM CONDENSER

10,000 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

SUCTION PRESSURE

HARVEST CYCLE TIME

HEAD PRESSURE

3.7
3.1

4.1

2.5

31

28
29

31

1036
1044
1055
1060

30

32
33
35

1028

1029
1040
1050
1051

1020
1027
1029

27

APPROXIMATE ICE

PRODUCTION PER 24 HR.

APPROXIMATE ELECTRIC

CONSUMPTION

APPROXIMATE WATER

CONSUMPTION PER 24 HR.

FREEZING CYCLE TIME

WATER TEMP. (ºF/ºC)

AMBIENT TEMP.

(ºF/ºC)

50/10

70/21

90/32

28

28

30

2.7

4.7

3.4

4.1
3.4

2.8

4.3

ENG.F-011.1.0205

Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in

bold

should be used for reference only.

2. We reserve the right to make changes in specifications and design without prior

notice.

2. KM-650MWH (water-cooled)