Remote air-cooled model) – Hoshizaki KM-901MWH User Manual

Page 78

Advertising
background image

78

Fig. 4

Adjustment Screw

CW – Higher
CCW – Lower

Top View

18) Check for water leaks.
19) Replace the panels in their correct positions.
20) Turn on the power supply.

J. Adjustment of Water Regulating Valve (water-cooled model)

The water regulating valve (also called "water regulator") is factory set, and generally no
adjustment is required. However, when necessary, adjust the water regulator using the
following procedures.

1) Prepare a thermometer to check the condenser drain temperature. Attach a pressure

gauge to the high-side line of the system.

2) Five minutes after a freeze cycle starts,

confirm that the thermometer reads 104°F
to 115°F (40°C to 46°C). If it does not,
rotate the adjustment screw by using a flat
blade screwdriver until the temperature
is in the proper range. See Fig. 4. Next,
check that the reference pressure is in the
range indicated in the Head Pressure table
in the Performance Data section. If it is not
in the proper range, verify the refrigerant
charge.

3) Check that the condenser drain temperature is stable.

K. Removal and Replacement of Headmaster (Condensing Pressure

Regulator - C.P.R.) (remote air-cooled model)

CAUTION

1. Always install a new drier every time the sealed refrigeration system is

opened.

2. Do not replace the drier until after all other repair or replacement has been

made. Install the new drier with the arrow on the drier in the direction of the
refrigerant flow.

3. When brazing, protect the headmaster and drier by using wet cloths to

prevent the headmaster and drier from overheating. Do not allow the
headmaster or drier to exceed 250°F (121°C).

1) Turn off the power supply.
2) Remove the panels from the remote condenser unit.
3) Recover the refrigerant and store it in an approved container.
4) Before heating, break off the stub on the dome to release the dome charge.
5) Disconnect the headmaster.
6) Place the new headmaster in position.
7) Remove the drier, then place the new drier in position.

Advertising
This manual is related to the following products: