H46C HUMIDITY CONTROLLER

H46C

HUMIDITY CONTROLLER
RISE

DEHUMIDIFIER

L1

EXHAUST FAN

(HOT)

1

1

OR AIR

POWER

CONDITIONER

SUPPLY

L2

PROVIDE DISCONNECT MEANS AND OVERLOAD

M7923

PROTECTION AS REQUIRED.

Fig. 2. Typical H46C wiring diagram.

Connections and Operation

A dehumidistat in combination with the thermostat can be
used to run the air conditioner to control relative humidity
levels. The dehumidistat and thermostat can be wired in
parallel or in series.

Wiring in parallel allows the dehumidistat to indepen­
dently control the humidity level, but could cause
overcooling of the home. During unoccupied times, the
homeowner should set the thermostat to a relatively high
setting and control moisture using the dehumidistat.

Wiring in series prevents overcooling but the air

conditioner runs only when both the thermostat and
dehumidistat are calling. During unoccupied times, the

homeowner should set the thermostat to a relatively low

setting and control moisture using the dehumidistat.

SETTING AND ADJUSTMENT

The H46 makes contact on a relative humidity rise to the
setpoint to start the dehumidifier. On a decrease in
relative humidity to the setpoint (minus the differential),
the switch breaks contact to stop the dehumidifier. Turn
the knob clockwise to the setting stop to place the H46 in
the On position. Turn the knob counterclockwise to the
setting stop to place the H46 in the Off position.

CHECKOUT

After completing all mounting and wiring, turn on the
power supply. Place the system into operation by turning
the setting knob toward the low end of the scale until the
dehumidifier motor starts. Turn the setting knob slowly
toward the high end of the scale until the dehumidifier

motor stops.

H46C

T87F/Q539A INTERNALSCHEMATIC

TEMPERATURE
FALL

1

2

3

PROVIDE OVERLOAD PROTECTION AND DISCONNECT MEANS
AS REQUIRED.

HEATING DAMPER MOTOR, IF USED.

CLOGGED FILTER SWITCH OR COOLING PANEL CONNECTION.

1

3

2

B

X

O

R1

W

Y

W1

Y1

G

R

H

R

HEAT

OFF

FAN

AUTO

ON

COOL

HEAT

OFF

COOL

FIXED
COOL
ANTICIPATOR

ADJUSTABLE
HEAT
ANTICIPATOR

HEATING
RELAY OR
VALVE COIL

COOLING
CONTACTOR
COIL

FAN RELAY
COIL

FILTER
LIGHT

T87F

M7913

Fig. 3. Typical parallel wiring hookup for H46C with T87F/Q539A combination

for dehumidification and mildew control.