Pump placement, 16 operation, Head – HONDA WH15X User Manual
Page 18
16
OPERATION
PUMP PLACEMENT
SUCTION
HEAD
DISCHARGE
HEAD
T
T
O
O
T
T
A
A
L
L
H
H
E
E
A
A
D
D
For best pump performance, place the pump near the water level, and
use hoses that are no longer than necessary. That will enable the
pump to produce the greatest output with the least self-priming time.
As
head
(pumping height) increases, pump output decreases.
Maximum head specifications and pump performance curves are
shown in the tables on pages
. The length, type, and size of
the suction and discharge hoses can also significantly affect pump
output.
Discharge head capability is always greater than suction head
capability, so it is important for suction head to be the shorter part of
total head.
Minimizing suction head (placing the pump near the water level) is
also very important for reducing self-priming time. Self-priming time
is the time it takes the pump to bring water the distance of the suction
head during initial operation.
07/06/05 14:20:01 31YB7720_017