Air Filter Maintenance

22

www.honeywellgenerators.com

HW6200/HW6200L Portable Electrical Generator Owner’s Manual

6.

Soak air filter in clean engine oil.

7.

Squeeze out excess oil.

NOTE:

Engine will smoke during initial start-up if too much oil is
left in filter.

8.

Reassemble the air cleaner assembly:

For HW6200L Model:

8A. Reinstall the light grey foam air filter.

8B. Reinstall the dark grey foam air filter.

8C. Reinstall the air cleaner cover and lock the latches at
the top and bottom.

For HW6200 Model:

8A. Reinstall the metal air filter plate in the support brack-
ets if it fell out during air filter removal.

8B. Reinstall air filter.

8C. Reinstall air cleaner cover.

FIGURE 40: Oil Air Filter

FIGURE 41: Excess Oil Removal

Frequent or prolonged contact with engine oil may cause
skin cancer.

• Thoroughly wash hands and any areas of skin exposed

to used oil with soap and water.

FIGURE 42: Air Filter Installation—HW6200L Model

CAUTION

FIGURE 43: Air Filter Plate Installation—HW6200 Model