User maintenance procedures, Periodically .......... ❑ monthly, Main burner flames – Honeywell Series 4 User Manual

Page 7: Continued test low water cutoff, Clean vent termination and air intake screens

Advertising
background image

Part number 550-141-893/0800

7

AHE Series 4 Direct Vent Wall-Mounted Boilers — User’s Information Manual

Main burner flames

1.

See Figure 4. Remove burner input plenum cover
plate “A”.

2.

Visually inspect burner flames:

Proper

main burner flame (see Figure 5):

a.

Yellow-orange streaks may appear (caused
by dust).

Improper

main burner flame:

a.

Overfired — Large flames.

b.

Underfired — Small flames.

c.

Lack of primary air — Yellow tipping on
flames (sooting will occur).

Figure 5

Main burner flame, typical

26024

Transparent

blue flame

Inner flame

User maintenance procedures

continued

Test low water cutoff

Test the low water cutoff periodically during the heating
season, following the low water cutoff manufacturer’s
instructions.

Clean vent termination and air
intake screens

1.

Remove all lint and debris from both the boiler air
intake screen and the flue discharge screen.

2.

The boiler control module will sense blockage of
the air intake or flue and lockout if the blockage is
excessive. It will signal by flashing the appropriate
indicator lights on the control board.

3.

If removing the debris does not allow the boiler to
operate correctly afterwards, contact your qualified
service technician to inspect the boiler and vent/
air systems.

Periodically ..........

Monthly .....................

89301