Honeywell BENDIX/KING KLN 94 User Manual

Page 94

Advertising
background image

B

KLN 94

Rev. 4, Jan/2003 10599I04.CDL

Page A-4

FORMAT B (52 BYTE ASCII STRING)

BYTE

DESCRIPTION

1

STX (ASCII code 02H)

2

Unit of Measure

G = .1 gallon
I = .1 imperial gallon
L = 1 liter
K = 1 kilogram
B = 1 pound

3-8

Total Fuel Remaining

ASCII-coded decimal format (least significant digit is tenths), LSB first

Example:
A fuel remaining value of 543.2 would be sent as “2.3450” (32H, 2EH, 33H, 34H, 35H,
30H).

9

Total Fuel Remaining Checksum

Break each decimal value into BCD representation. Using BCD arithmetic, sum the 4
BCD values and convert the lower-order BCD digit to an ASCII coded numeric digit.

Example:
The checksum for a value of 543.2 would be “4” (34H).

10-15

Total Fuel Flow Rate

ASCII-coded decimal format as for Total Fuel Remaining.

16

Total Fuel Flow Rate Checksum

Sum of fuel flow bytes computed as for Total Fuel Remaining.

17-22

Engine One Fuel Flow Rate

ASCII-coded decimal format as for Total Fuel Remaining

23

Engine One Fuel Flow Rate Checksum

Sum of Left Engine Fuel Flow Rate bytes computed as for Total Fuel Remaining

24-29

Engine Two Fuel Flow Rate

ASCII-coded decimal format as for Total Fuel Remaining.

Advertising