Honeywell BENDIX/KING KLN 94 User Manual

Page 97

Advertising
background image

B

KLN 94

Rev. 4, Jan/2003 10599I04.CDL

Page A-7

FORMAT C (108 BYTE ASCII STRING) - con’t

BYTE

DESCRIPTION / FORMAT

71-76

Density Altitude (DALT, feet)

ASCII-coded decimal format with a sign character, as for PALT.

77

Density Altitude Checksum

Sum for DALT bytes, excluding the sign character, as for PALT.

78-80

Total Air Temperature (×C)

ASCII-coded decimal format with a sign character

Example:
An OAT of 25×C would be sent as “52+”.

81

Total Air Temperature Checksum

Sum for total air temperature bytes, excluding the sign byte, as for PALT.

82-84

Wind Direction (degrees from true North)

ASCII-coded decimal format

Example:
122 degrees would be sent as “22” (32H, 32H, 31H).

85

Wind Direction Checksum

Sum for wind direction bytes, as for IAS

86-88

Wind Speed (knots)

ASCII-coded decimal format, as for IAS

89

Wind Speed Checksum

Sum for wind speed bytes, as for IAS

90-92

Drift (degrees)

ASCII-coded decimal format with a direction character

Example:
7 right would be sent as “70R”, 14 left would be sent as “41L”.