SERVICE ENGINEER

GUIDE TO FAULT FINDING

IS THERE 230V ON TERMINAL

S3 OF MAINS INLET PLUG

IS THERE 230V ON TERMINAL 2

OF BOILER STAT (RED WIRE)

IS THERE 230V ON TERMINAL

ON BOILER LIMIT WITH RED AND

PURPLE WIRE.

CHECK FUNCTION OF BOILER

LIMIT THERMOSTAT

(CHECK FUNCTION OF OVERHEAT

INDICATOR LIGHT)

REFER TO BURNER FAULT

FINDING SECTION

CHECK FUSE/EXTERNAL

HEATING CONNECTIONS

CHECK FUNCTION OF

BOILER THERMOSTAT

CHECK CONNECTION

OF PLUGS TO BURNER

CONTROL BOX

BOILER NOT WORKING - ENSURE THERMOSTAT IS SWITCHED ON

YES

NO

YES

NO

NO

NO

YES

YES

YES

IS THE BURNER LOCK OUT

LIGHT ILLUMINATED

IS BLOCKED FLUE LIGHT

ILLUMINATED

REFER TO FAULT FINDING

SECTION

NO