Honeywell DCP552 Mark II User Manual

Page 126

Advertising
background image

7-27

0 to 3600sec

When set to 0, operation continues regardless of outage

time.

[Description:]

The HOLD mode is invoked when the outage is longer

than set time.

The measurement of a power outage may vary by about

10 seconds.

0: No

1: Yes

0

C 39

39

Manipulated variable setting

in PV overrange (CH2)

-5 to +105%

0.0

C 40

40

Manipulated variable in PV

overrange (CH2)

0: smooth

1: preset

0

C 41

41

Manual change mode (CH2)

-5 to +105%

0.0

C 42

42

Preset manual value (CH2)

0: oxygen pressure (PO

2

) computation

1: CP computation for NKG sensor

2: CP computation for Marathon monitors and Cambridge

sensors

3: CP computation for Corning sensors

4: CP computation for AACC sensors

5: CP computation for Barber-Coleman sensors

6: CP computation for Furnace Control sensors

[Description:]

Т------У is displayed for a model without CP compensation

and setting cannot be performed.

1

C 44

44

CP computation type (varies

with sensor manufacturer)

0

C 43

43

Length of outage permitting

continuous operation

[Description:]

Т-----У is displayed and setting cannot be performed.

----

C 51

51

Unused

----

C 52

52

0: SP1

1: PV1

2: Deviation1 (DEV1)

3: Manipulated variable 1 (MV1)

4: SP2

5: PV2

6: Deviation 2 (DEV2)

7: Manipulated variable 2 (MV2)

8: O

2

sensor mV input value

[Description:]

Т-----У is displayed and setting cannot be performed on

model without auxiliary output or with one auxiliary

output.

0

C 48

48

Auxiliary output type 2

----

C 53

53

Unused

Unused

----

C 54

54

Unused

----
----

C 55

55

C 56

56

Unused
Unused

0: SP1

1: PV1

2: Deviation1 (DEV1)

3: Manipulated variable 1 (MV1)

4: SP2

5: PV2

6: Deviation 2 (DEV2)

7: Manipulated variable 2 (MV2)

8: O

2

sensor mV input value

[Description:]

Т-----У is displayed and setting cannot be performed on

model without auxiliary output.

0

C 45

45

Auxiliary output type 1

Ð19999 to +20000 SPU (

C45

not equal to 3, 7)

Ð1999.9 to +2000.0 SPU (

C45

set to 3, 7)

[Description:]

Т-----У is displayed and setting cannot be performed on

model without auxiliary output.

0 SPU

C 46

46

Auxiliary output 1 lower limit

(4mA)

10000SPU

C 47

47

Auxiliary output 1 upper limit

(20mA)

Ð19999 to +20000 SPU (

C48

not equal to 3, 7)

Ð1999.9 to +2000.0% (

C48

set to 3, 7)

[Description:]

Т-----У is displayed and setting cannot be performed on

model without auxiliary output or with one auxiliary

output.

0 SPU

C 49

49

Auxiliary output 2 lower limit

(4mA)

10000SPU

C 50

50

Auxiliary output 2 upper limit

(20mA)

Item code

Item

No.

User

settings

Settings and descriptions

Factory default

settings

Chapter 7. PARAMETER SETUP