Dcp552 parameter work sheet – Honeywell DCP552 Mark II User Manual

Page 212

Advertising
background image

3

DCP552 Parameter Work Sheet

No. Item code

Item

Factory default User

Settings and descriptions

settings

settings

79

PA 79

PV2 equalizer compensation point No. 5 2000 PVU

–19999 to +20000 PVU(PV2)

80

PA 80

PV2 equalizer compensation amount No. 5 0 PVU

–1000 to +1000 PVU(PV2)

81

PA 81

PV2 equalizer compensation point No. 6 2500 PVU

–19999 to +20000 PVU(PV2)

82

PA 82

PV2 equalizer compensation amount No. 6 0 PVU

–1000 to +1000 PVU(PV2)

83

PA 83

PV2 equalizer compensation point No. 7 3000 PVU

–19999 to +20000 PVU(PV2)

84

PA 84

PV2 equalizer compensation amount No. 7 0 PVU

–1000 to +1000 PVU(PV2)

85

PA 85

PV2 equalizer compensation point No. 8 3500 PVU

–19999 to +20000 PVU(PV2)

86

PA 86

PV2 equalizer compensation amount No. 8 0 PVU

–1000 to +1000 PVU(PV2)

87

PA 87

PV2 equalizer compensation point No. 9 4000 PVU

–19999 to +20000 PVU(PV2)

88

PA 88

PV2 equalizer compensation amount No. 9 0 PVU

–1000 to +1000 PVU ( PV2 )

89

PA 89

PV2 equalizer compensation point No. 10 Range upper

PV2 range upper limit value (tied)

limit value

90

PA 90

PV2 equalizer compensation amount No. 10 0 PVU

–1000 to +1000 PVU(PV2)

93

PA 93

Auto-tuning (CH2)

0

0 : AT not performed
1 : standard AT performed on currently used PID group in

mode other than READY mode.

2 : AT writing overshoot-proof PID values to currently used

PID groups in mode other than READY mode performed.

3 : Standard AT performed on PID groups A1 to A7 in

READY mode.

4 : AT writing overshoot-proof PID values to PID groups A1

to A7 in READY mode continuously performed.

94

PA 94

Auto-tuning MV lower limit (CH2) 0.0

-5.0 to upper limit %

95

PA 95

Auto-tuning MV upper limit (CH2) 100.0

Lower limit to +105%

96

PA 96

PID computation initialize (CH2) 0

0 : No initialization during advance processing and PID

group change

1 : Initializes during advance processing but not during PID

group change

2 : No initialization during advance processing but

initializes during PID group change

3 : Initializes both during advance processing and PID

group change

97

PA 97

CPU computation compensation 0

0 : no compensation
1 : compensates

98

PA 98

CP value (PV) display lower limit value 0.000

0 to upper limit SPU (CH2)

99

PA 99

CP value (PV) display upper limit value 4.000

lower limit to 4000 SPU (CH2)

100

PA100

Gas constant

23.5

10.0 to 50.0

101

PA101

CP computation compensation 0.000

0 SPU (CH2) (tied)

No.1 compensation point

102

PA102

CP computation compensation 0.000

-1000 to +1000 SPU (CH2)

No.1 compensation amount

103

PA103

CP computation compensation 0.200

0 to 2000 SPU (CH2)

No.2 compensation point

104

PA104

CP computation compensation 0.000

-1000 to +1000 SPU (CH2)

No.2 compensation amount

105

PA105

CP computation compensation 0.400

0 to 2000 SPU (CH2)

No.3 compensation point

106

PA106

CP computation compensation 0.000

-1000 to +1000 SPU (CH2)

No.3 compensation amount

107

PA107

CP computation compensation 0.600

0 to 2000 SPU (CH2)

No.4 compensation point

108

PA108

CP computation compensation 0.000

-1000 to +1000 SPU (CH2)

No.4 compensation amount

109

PA109

CP computation compensation 0.800

0 to 2000 SPU (CH2)

No.5 compensation point

110

PA110

CP computation compensation 0.000

-1000 to +1000 SPU (CH2)

No.5 compensation amount

denotes items settable only on models with CP compensation