•When there is a G.SOAK wait at the start of a segment and the ON Time is set to

0, the output goes on at the start of the G.SOAK wait and the On Time starts as
the G.SOAK wait ends.
The output time = G.SOAK time + (Off Time – On Time) (See segment 8 in the
figure.)

•An On Time and Off Time occurring at the end of a RAMP-X segment are valid

when there is a G.SOAK wait at the end of a segment or as the end state of the
final segment. (See segment 10 in the figure.)
Note, however, that an On Time or Off Time setting at the end of a RAMP-T
segment is either valid or invalid depending on the computational error.

Chapter 5. FUNCTIONS

On-time

Off-time

Output-ON

Output-OFF

8

G.SOAK wait

Start of segment 8

The output goes on at the start of
segment 8 when on is set to 0.

Segment

Time

On-time

Off-time

Output-ON

Output-OFF

9

ON = Segment time

10

Segment time

G.SOAK wait

ON = Segment time

Segment

On-time

Off-time

Output-ON

Output-OFF

Segment

Time