Appendix A: Fuel Conversion

CONVERTING THE CLARITY FIREPLACE
INSERT FROM ONE GAS TO ANOTHER IN
THE FIELD

NOTE: THE CONVERSION SHALL BE CAR-

RIED OUT IN ACCORDANCE WITH THE RE-
QUIREMENTS OF THE PROVINCIAL OR LO-
CAL AUTHORITIES HAVING JURISDICTION
AND IN A CC OR DA NC E WITH R EQUIRE-
MENTS OF THE CURRENT EDITION OF THE
NATIONAL FUEL GAS CODE, ANSI Z223.1 or
the CAN/CGA-B149 INSTALLATION CODES.

CONVERSION KIT COMPONENTS

• Burner system module

• Conversion label

The Clarity Fireplace Insert is designed to burn

either natural gas or propane, but requires a dedi-
cated burner system module for either fuel. Conver-
sion to the alternate fuel is a simple matter of replac-
ing one burner system module with another. A label
on the burner system module will specify for which
fuel it is intended.

To accomplish the conversion procedure, follow

these steps.

1. Remove the trim panels and the glass door ac-

cording to the directions on page 12.

2. Disconnect the electrical connections and the gas

line fitting from the module.

3. Remove the cross log, the front logs, and the two

ember strips following the directions on page 7.

4. Pull the module out an inch or so so that there is

enough room to remove the rear log.

5. Remove the Burner System Module

The module can be removed as an integrated unit

by simply pulling the module forward.

6. Install the replacement module, re-install the logs,

re-connect the wiring connections and gas line fit-
ting, secure the glass door, and replace the trim pan-
els.

After completing the fuel conversion, an installer

fuel label—supplied with the burner system mod-

ule—must be filled out by the installer and attached
to the stove.

SEE WIRING DIAGRAM ON PAGE 18

The above label on the Clarity's burner system module indicates
that the unit is equipped to burn natural gas. A similar label is
used for Propane.

CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING CONTROLS. WIRING ER-
RORS CAN CAUSE IMPROPER AND DANGEROUS
OPERATION. VERIFY PROPER OPERATION AFTER
SERVICING.

PROPANE

NATURAL

HARMAN CLARIT Y GAS

FI REPLACE INSERT

44