3 - 5

Note: Manual Trigger, Low Power cannot be used with keyboard wedge

applications.

Low Power Time-Out Timer

Scan the Low Power Time-Out bar code to change the time-out duration (in
seconds). Then scan the time-out duration (from 0-300 seconds) from the inside
back cover, and

Save

.

Default = 120 seconds.

If the unit remains idle during the low power time-out interval, the unit goes into
low power mode. Whenever the trigger is enabled, the low power time-out timer
is reset.

Note: This time-out does not begin until the imager time-out setting has expired.

Scan Stand Mode

When a unit is in Scan Stand mode, it remains idle as long as it sees the Scan
Stand symbol. (See

Scan Stand Symbol

on page 3-6.) When a different code is

presented, the imager is triggered to read the new code.

Note: The imager automatically adjusts the illumination LEDs to the lowest light

level possible to maintain a good lock on the Scan Stand symbol. When
a symbol is presented, the imager’s light levels adjust to the saved setting
(see

LED Power Level

on page 3-9). This mode requires at least 50 lux

of ambient light to operate correctly.