HW7500E/HW7500EL Portable Electrical Generator Owner’s Manual

www.honeywellgenerators.com

17

Preparing for Operation

Manual (Recoil) Start:

1.

Be sure generator is placed outside, in well-ventilated
area.

2.

Confirm the circuit breakers are set.

3.

Turn fuel valve to ON position.

4.

Move choke control to ON position.

5.

Press engine control switch to RUN position.

6.

Grip recoil starter handle and pull slowly until you feel
slight resistance.

7.

Apply a swift, single pull to start engine. Carefully
return recoil starter handle to its original position.

8.

As engine warms up, and RPM stabilizes, gradually
move choke control to OFF position.

NOTICE

Keep the generator at a minimum of 6 feet (2 meters) from
any building, object, or wall.

FIGURE 26: Circuit Breaker Position

FIGURE 27: Fuel Valve Lever — ON/OFF position

FIGURE 29: Choke Lever

Set

Tripped

ON

OFF

FIGURE 30: Engine Control Switch

Kickback (rapid retraction) of starter cord will pull hand and
arm toward engine faster than you can let go.
Broken bones, fractures, bruises, or sprains could result.

FIGURE 32: Recoil Starter Handle

NOTICE

To prevent damage to generator, do not allow recoil starter
handle to snap back against engine.

NOTICE

If engine will not start, move the choke to the OFF posi-
tion to reduce fuel to the engine.